VOLTSVERDEAudit · Automation · Electrical

Electrical installation survey

Electrical wiring and installation surveys involving measurements are recommended when voltage fluctuates, components overheat or circuit breakers and RCDs trip. We check electrical parameters, accessible connections and protective devices to identify the cause and determine appropriate next steps.

Electrical metering equipment

When the service is needed

  • Repeated trips of circuit breakers or residual-current devices.
  • Overheating, smell of heated materials, unstable lighting or power.
  • Higher power demand, new equipment or a backup source.
  • Review after extended use, flooding or work by other contractors.

Scope of checks

Distribution boards

Review accessible devices, labels, busbars and connections, and compare circuits with available drawings.

Loads and supply parameters

Measure voltage, current and phase load distribution; longer-term logging is arranged when necessary.

Protective circuits

Assess protective conductors, protective devices and RCD test results; specialist measurements follow the test plan.

Connection heating

Visually assess signs of overheating; thermal imaging under suitable load and safe conditions when agreed.

Power sources

Review accessible backup circuits, transfer logic and inverter or UPS limitations.

Cable condition

Review accessible routes, documentation and insulation test results; concealed routes are assessed only by feasible methods.

Work sequence

Initial brief

Clarify symptoms, equipment and access.

Survey

Agreed checks and measurements under safe conditions.

Engineering findings

Analyze results and identify next steps.

Handover

Record findings, limitations and recommendations.

What the client receives

The client receives a description of actual condition, observed deviations, recommendations for further testing and correction priorities. Insulation, loop and RCD measurements are undertaken subject to agreed scope, suitable instruments and safe access; official reports are arranged separately with an electrical laboratory.

Questions before work begins

Can the cause of a trip be established in one visit?

Not always. Intermittent faults may require logging and repeat checks under representative load.

Does power need to be isolated?

Some work requires isolation. Arrangements are agreed with the owner before measurements.

What if there is a burning smell or sparking?

Stop using the affected equipment, isolate the supply if safe to do so and contact a qualified specialist. If there is a fire risk, call emergency services.

What is checked when voltage fluctuates or overvoltage occurs?

We assess power supply parameters, connection condition and existing protection. Intermittent faults may require recording network parameters.